Shenzhen Wensidun Technology Co., Ltd.

Keep Improving

Manufacturer from China
Active Member
3 Years
Home / Products / Avian Influenza Rapid Test Kit /

Pullorum Disease Pd Fowl Typhoid Ft Ab Check Rapid Test Kit For Antibody

Contact Now
Shenzhen Wensidun Technology Co., Ltd.
City:shenzhen
Contact Person:MrZhang
Contact Now

Pullorum Disease Pd Fowl Typhoid Ft Ab Check Rapid Test Kit For Antibody

Ask Latest Price
Video Channel
Brand Name :Green Spring
Model Number :LSY-30027
Certification :ISO13485,ISO9001
Place of Origin :China
MOQ :1kit
Price :Negotiable
Payment Terms :T/T
Supply Ability :100000 tests per day
Delivery Time :7~14days
Shelf Life :12 months; date of production is on box.
Key words :Pullorum Disease (PD) and Fowl Typhoid (FT) Ab ELISA Kit
Specification :96 Wells/Kit
Sample Performance :chicken serum
Type :Avian Influenza Rapid Test Kit
Store :Storing at 2-8℃, in the dark.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Pullorum Disease (PD) and Fowl Typhoid (FT) Antibody ELISA Kit 96 Wells/Kit

1. Usage


This kit is used to detect Pullorum Disease (PD) and Fowl Typhoid (FT) antibody in chicken serum, to assist diagnosis of serological infected chicken.


2. Principle


The Pullorum Disease (PD) and Fowl Typhoid (FT) antibody ELISA kit is based on an indirect enzymatic immunoassay (Indirect ELISA).The antigen is coated on plates. When a sample serum contains specific antibodies against virus, they will bind to the antigen on plates. Wash the unbound antibodies and other components. Then add a specific enzyme conjugate. After incubation and washing, add the TMB substrate. A colorimetric reaction will appear, measured by a spectrophotometer (450 nm).


3. Reagents

PD&FT antigen coated microtiter strips 1 piece (96 wells)
Enzyme Conjugate 1 bottle (11 mL/bottle)
10× washing solution 1 bottle (50 mL/bottle)
Substrate A /B solution 1 tube each (6 mL/tube)
Sample dilution 1 bottle (50 mL/bottle)
Stop solution 1 tube (6 mL/tube)
Negative control 1 tube (800μL /tube)
Positive control 1 tube (800μL /tube)
Serum dilution plate 1 piece
Adhesive film 2 pieces
Instruction 1 piece


4. Materials required but not provided


1) Micropipettors and disposable tips: 0.5μL~10μL,10μL~100μL,100μL~1000μL
2) 37 ℃ Incubator
3) Measuring cylinder: 500 ml
4) 96 wells microplate reader
5) Distilled water or deionied water
6) Bottle or microplate washing machine


5. Sample preparation


Take animal whole blood, make serum according to regular methods, the serum should be clear, have no hemolysis.


6. Preparation of washing buffer


Return washing solution to room temperature before use, if there is salty crystals, shake to make the crystals dissolve, then use distilled water or deionied water to dilute it at 10 times. The diluted washing solution can store for 1 week at 4 ℃.


7. Sample dilution


At serum dilution plate, dilute serum at 1:99 with sample dilution (for example: 495μL sample diluent + 5μL serum)
Notice: Negative control and Positive control do not need dilute. Exchange tip after taking sample every time, record the situation of the sample on plate accurately. Shake the sample evenly before adding it.


8. Notes


1) All reagents should be adjusted to the room temperature and shake evenly before using, store at 2-8 ℃after using
2) Do not exchange the reagents from the kits of different lot numbers to use. Avoid reagent pollution when using.
3) Substrate and stop solution may have excitant to skin and eyes, pay attention when using.
4) Do not expose TMB (Substrate B) to light and avoid it contact with antioxidants.
5) The wells should avoid damp or touching water after unsealing (Put the un-using microplate back to bag with dehydrator in 2~8 ℃soon )
6) Deal all waste reasonable before dumping to avoid pollution.
7) Strictly adhere to instruction to get best result. All procedure including pipetting, timing and washing etc. must be accurate.
8) Serum dilution plate is disposable, do not use for second time; the MAX volume of it is 300μL/well.


9. ELISA procedure


1) Take pre-coated microplate (Can unseal for several time use as per sample quantity), add 100μL diluted serum to a well, meanwhile set 1 wells for Negative control, Positive control and blank control wells separately. Add 100 μL Negative/Positive control to its wells, only add 100μL sample dilution in the blank control wells. Shake softly (do not spill),incubate at 37℃ for 30 min.
2) Pour the liquid out of the wells, add 250 μL diluted washing solution to each well, static for 1 min, pour out. Repeat 3 times, then pat to dry on absorbent paper.
3) Add 100 μL Enzyme Conjugate (except blank wells) to each well, andincubate at 37℃ for 30 min.
4) Repeat the step 2(washing). Remember pat to dry on absorbent paper at last.
5) Add 50 μL substrate A, then substrate B (50 μL) to each well, mix properly,react for 10 min at 37℃ in dark.
6) Add 50 μL stop solution in each well, and measure the result within 10 min.


10. Results


Set zero for the blank well, and test the A450nm (630 nm as a reference) value on the microplate-reader. The conditions for the test to be tenable are that the positive control wells’ A450nm value is greater than or equal to 0.5, and the negative control wells’ A450nm value is less than 0.15. If the test is invalid, the operation is in doubt, retest and observe all the reagents carefully.
If the sample’s A450 value is greater than 0.2+ absorbance of negative control mean, it is judged to be positive; and if less than 0.2+ absorbance of negative control mean, negative. If absorbance of negative control mean is less than 0.05, calculate as 0.05

Specifications: 96 wells/kit.
Expiry date:12 months.
Storage: Storing at 2-8℃, in the dark.

Pullorum Disease Pd Fowl Typhoid Ft Ab Check Rapid Test Kit For Antibody

Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.

Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific needs and specific quantities.

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so far all the production process, we have standard rules, we comply with the relevant behavior and laws of the government.

Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service. If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.

Q5: What is your minimum order quantity?
A5: 1Kit.

Q6: What is the shipping method?
A6: It can be shipped by express (FEDEX, UPS, DHL, EMS, etc.) or by air and ground.Please confirm with us before placing an order.

Inquiry Cart 0